FUEL CELL INVERTER FOR SYSTEM COORDINATION

               ・Smaller,lighter and more efficient compared with other companies'products
               ・Easy to treat and install this product
               ・Possible to operate it remotely
               ・Operation and trouble indications on LED
               ・Ripple current of DC input side is within 5%



1KW
1KW

Itemsl Specifications and standards
DC Input 35V〜60V 40V〜70V or 35V〜70V
AC Output Single phase 115V/120V/200V/220V  50/60Hz
(possible to output by single phase three wires)
Efficiency 93%(90%Min,in DC input 35V〜60V)
Power factor 0.7〜1.0Max.in 20%〜100% load
Input side ripple rate 3% Max.
Display Input voltage,current and electric power voltage,
current and conversion efficiency
Coordination Commercial power supply system coordination
current control (numerical display)
Dimensions H165×W360×D233m/m (installation type)
Weight 9.5kg
Rating Continuous
Cooling system Compulsory cooling
Main ciruit method Voltage type of current control PWM inverter
Isolation system High frequency isolation
Electric power control system By direct current voltage from the outside
Output control system Current control system
Subsidiary control Soft start
Operation control Automatic start
Start/stop by watch of,direct current voltage
Start condition:35V DC Min,for 1 min,for 1 min
successively or 40V DC min,for 1sec, successively
DC
input
Rated voltage 48V DC
Rated current 30A DC (0〜50A but the output is up to 1.3kw Max
Input fluctuation
voltage
35V〜70V DC
Current ripple rate 5% Max.( peak to peak )
System
corditions
Phase Single phase three wires
Voltage 220V
Voltage change range ±13V
Frequency 60Hz
Frequency change range ±0.3% Max.
Power
generation
output
coordinative
operation
Output capacity 1300W Max.
Conversion efficiency 90% Min
Output power factor 0.95 Min
Harmonics current Total current distortion factor 5% Max.
Each current distortion factor 3% Max.
Independent
operation
Rating Load capacity 1000VA
Rated voltage 220V
Constant voltage accuracy ±3% Max
Waveform distortion 3% Max.
Endurance amount of
fault load
110% (100%=4.54A)
Transient voltage fluctuation ±7% Max.
Frequency accuracy ±0.1Hz Max.
Coordinated
protection
Coordinated protection relay Alternating,current,fault voltage protection,
alternating current instant fault voltage,
Frequency rise detection,Frequency decline
detection,alternating current voltage decline
detection,instant voltage decline detection
Independent operation Passive system Voltage phase jump
detection system
Active system Frequency shift system
Insulation resistance The 1st order-the 2nd order,electric current in block-outside box 10MΩ Min
Dielectric strength Electric current ,in block-outside box 1500V AC
for 1 minute
Noise 45db Max.(1m)
(Date communicacion on R232c)
It's possible to change inverter DC input voltage according to set value for fuel cell output voltage